1.
Sci Rep ; 11(1): 9951, 2021 05 11.
Artigo em Inglês | MEDLINE | ID: mdl-33976274

RESUMO

The combination of manifold optical imaging modalities resulting in multimodal optical systems allows to discover a larger number of biomarkers than using a single modality. The goal of multimodal imaging systems is to increase the diagnostic performance through the combination of complementary modalities, e.g. optical coherence tomography (OCT) and Raman spectroscopy (RS). The physical signal origins of OCT and RS are distinctly different, i.e. in OCT it is elastic back scattering of photons, due to a change in refractive index, while in RS it is the inelastic scattering between photons and molecules. Despite those diverse characteristics both modalities are also linked via scattering properties and molecular composition of tissue. Here, we investigate for the first time the relation of co-registered OCT and RS signals of human bladder tissue, to demonstrate that the signals of these complementary modalities are inherently intertwined, enabling a direct but more importantly improved interpretation and better understanding of the other modality. This work demonstrates that the benefit for using two complementary imaging approaches is, not only the increased diagnostic value, but the increased information and better understanding of the signal origins of both modalities. This evaluation confirms the advantages for using multimodal imaging systems and also paves the way for significant further improved understanding and clinically interpretation of both modalities in the future.

2.
Analyst ; 145(4): 1445-1456, 2020 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-31867582

RESUMO

Non-muscle-invasive bladder cancer affects millions of people worldwide, resulting in significant discomfort to the patient and potential death. Today, cystoscopy is the gold standard for bladder cancer assessment, using white light endoscopy to detect tumor suspected lesion areas, followed by resection of these areas and subsequent histopathological evaluation. Not only does the pathological examination take days, but due to the invasive nature, the performed biopsy can result in significant harm to the patient. Nowadays, optical modalities, such as optical coherence tomography (OCT) and Raman spectroscopy (RS), have proven to detect cancer in real time and can provide more detailed clinical information of a lesion, e.g. its penetration depth (stage) and the differentiation of the cells (grade). In this paper, we present an ex vivo study performed with a combined piezoelectric tube-based OCT-probe and fiber optic RS-probe imaging system that allows large field-of-view imaging of bladder biopsies, using both modalities and co-registered visualization, detection and grading of cancerous bladder lesions. In the present study, 119 examined biopsies were characterized, showing that fiber-optic based OCT provides a sensitivity of 78% and a specificity of 69% for the detection of non-muscle-invasive bladder cancer, while RS, on the other hand, provides a sensitivity of 81% and a specificity of 61% for the grading of low- and high-grade tissues. Moreover, the study shows that a piezoelectric tube-based OCT probe can have significant endurance, suitable for future long-lasting in vivo applications. These results also indicate that combined OCT and RS fiber probe-based characterization offers an exciting possibility for label-free and morpho-chemical optical biopsies for bladder cancer diagnostics.


Assuntos
Fibras Ópticas , Análise Espectral Raman , Tomografia de Coerência Óptica/instrumentação , Neoplasias da Bexiga Urinária/diagnóstico por imagem , Neoplasias da Bexiga Urinária/patologia , Linhagem Celular Tumoral , Colágeno/metabolismo , Humanos , Gradação de Tumores , Invasividade Neoplásica
3.
J Biomed Opt ; 25(3): 1-5, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31562707

RESUMO

We present coregistered images of tissue vasculature that allow a direct comparison between the performance of narrow-band imaging (NBI) and optical coherence tomography angiography (OCTA). Images were generated with a bimodal endomicroscope having a size of 15 × 2.4 × 3.3 3 ( l , w , h ) that combines two imaging channels. The white light imaging channel was used to perform NBI, the current gold standard for endoscopic visualization of vessels. The second channel allowed the simultaneous acquisition of optical coherence tomography (OCT) and OCTA images, enabling a three-dimensional (3-D) visualization of morphological as well as functional tissue information. In order to obtain 3-D OCT images scanning of the light-transmitting fiber was implemented by a small piezoelectric tube. A field of view of ∼1.1 mm was achieved for both modalities. Under the assumption that OCTA can address current limitations of NBI, their performance was studied and compared during in vivo experiments. The preliminary results show the potential of OCT regarding an improved visualization and localization of vessel beds, which can be beneficial for diagnosis of pathological conditions.


Assuntos
Endoscópios , Mucosa Bucal/diagnóstico por imagem , Imagem de Banda Estreita , Tomografia de Coerência Óptica , Capilares , Angiofluoresceinografia , Humanos , Imageamento Tridimensional , Mucosa Bucal/irrigação sanguínea
4.
Opt Lett ; 44(4): 967-970, 2019 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-30768032

RESUMO

We demonstrate a synthetic subaperture-based angle-independent Doppler flow calculation, using a line field spectral domain optical coherence tomography system. The high speed of the system features a high phase stability over the volume, which is necessary to apply synthetic subapertures in the aperture plane. Thus, the flow component for each subaperture can be reconstructed in postprocessing. Capillary phantom and in vivo retinal imaging experiments were performed to validate and demonstrate angle-independent Doppler flow calculation.


Assuntos
Fluxo Sanguíneo Regional , Vasos Retinianos/diagnóstico por imagem , Vasos Retinianos/fisiologia , Tomografia de Coerência Óptica , Humanos , Imageamento Tridimensional , Imagens de Fantasmas
5.
J Biophotonics ; 12(4): e201800382, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30652423

RESUMO

A forward imaging endoscope for optical coherence tomography angiography (OCTA) featuring a piezoelectric fiber scanner is presented. Imaging is performed with an optical coherence tomography (OCT) system incorporating an akinetic light source with a center wavelength of 1300 nm, bandwidth of 90 nm and A-line rate of 173 kHz. The endoscope operates in contact mode to avoid motion artifacts, in particular, beneficial for OCTA measurements, and achieves a transversal resolution of 12 µm in air at a rigid probe size of 4 mm in diameter and 11.3 mm in length. A spiral scan pattern is generated at a scanning frequency of 360 Hz to sample a maximum field of view of 1.3 mm. OCT images of a human finger as well as visualization of microvasculature of the human palm are presented both in two and three dimensions. The combination of morphological tissue contrast with qualitative dynamic blood flow information within this endoscopic imaging approach potentially enables improved early diagnostic capabilities of internal organs for diseases such as bladder cancer.


Assuntos
Angiografia/instrumentação , Endoscopia/instrumentação , Tomografia de Coerência Óptica/instrumentação , Artefatos , Dedos/diagnóstico por imagem , Humanos , Movimento
6.
J Biomed Opt ; 23(6): 1-8, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29900706

RESUMO

We demonstrate in vivo endoscopic optical coherence tomography (OCT) imaging in the forward direction using a flexible fiber bundle (FB). In comparison to current conventional forward-looking probe schemes, our approach simplifies the endoscope design by avoiding the integration of any beam steering components in the distal probe end due to two-dimensional scanning of a focused light beam over the proximal FB surface. We describe the challenges that arise when OCT imaging with an FB is performed, such as multimoding or cross coupling. The performance of different FBs varying in parameters, such as numerical aperture, core size, core structure, and flexibility, was consequently compared, and image quality degrading artifacts were described in detail. Based on our findings, we propose an optimal FB design for endoscopic OCT imaging.


Assuntos
Endoscópios , Endoscopia/métodos , Tecnologia de Fibra Óptica , Fibras Ópticas , Tomografia de Coerência Óptica/instrumentação , Desenho de Equipamento , Tomografia de Coerência Óptica/métodos
7.
Biomed Opt Express ; 9(2): 472-485, 2018 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-29552387

RESUMO

We demonstrate a high-resolution line field en-face time domain optical coherence tomography (OCT) system using an off-axis holography configuration. Line field en-face OCT produces high speed en-face images at rates of up to 100 Hz. The high frame rate favors good phase stability across the lateral field-of-view which is indispensable for digital adaptive optics (DAO). Human retinal structures are acquired in-vivo with a broadband light source at 840 nm, and line rates of 10 kHz to 100 kHz. Structures of different retinal layers, such as photoreceptors, capillaries, and nerve fibers are visualized with high resolution of 2.8 µm and 5.5 µm in lateral directions. Subaperture based DAO is successfully applied to increase the visibility of cone-photoreceptors and nerve fibers. Furthermore, en-face Doppler OCT maps are generated based on calculating the differential phase shifts between recorded lines.

8.
Biomed Opt Express ; 8(7): 3369-3382, 2017 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-28717573

RESUMO

Sub-aperture based digital adaptive optics is demonstrated in a fiber based point scanning optical coherence tomography system using a 1060 nm swept source laser. To detect optical aberrations in-vivo, a small lateral field of view of ~[Formula: see text] is scanned on the sample at a high volume rate of 17 Hz (~1.3 kHz B-scan rate) to avoid any significant lateral and axial motion of the sample, and is used as a "guide star" for the sub-aperture based DAO. The proof of principle is demonstrated using a micro-beads phantom sample, wherein a significant root mean square wavefront error (RMS WFE) of 1.48 waves (> 1[Formula: see text]) is detected. In-vivo aberration measurement with a RMS WFE of 0.33 waves, which is ~5 times higher than the Marechal's criterion of [Formula: see text] waves for the diffraction limited performance, is shown for a human retinal OCT. Attempt has been made to validate the experimental results with the conventional Shack-Hartmann wavefront sensor within reasonable limitations.